This method describes how to determine the hard resin fraction in hops and hop products; for the procedure, refer to the MEBAK method R-300.03.901 [2016-03].
Hops and hop products intended for use in beer brewing or elsewhere in the food industry
The hard resins are calculated by subtracting the soft resins from the total resins. This yields the hard resin content as a percentage of the total resins.
This method describes how to determine the hop storage index (HSI) in hops and hop products.
Hops and hop products intended for use in beer brewing or elsewhere in the food industry
The oxidative degradation of the α-acids and β-acids in hops and conventional hop products is determined using a spectrophotometer. The HSI can be referenced in addition to or together with the spectrophotometric method for determining the α-acids and β-acids in hops outlined under R-300.04.110 α- und β-Säuren in Doldenhopfen und Hopfenpellets – Spektralphotometrische Methode.
Barley malt intended for use in beer brewing or elsewhere in the food industry
High-molecular weight dextrins and starch present in the wort extracted from brewery spent grains are precipitated through the addition of ethanol, centrifuged and dissolved in phosphate buffer, followed by the addition of an iodine solution. Depending upon the molecular weight and degree of branching, a red to blue color forms, the intensity of which is measured spectrophotometrically at 578 nm.
This method describes how to conduct a stress test for non-alcoholic beverages (NAB).
non-alcoholic beverages (soft drinks containing natural aromas and flavors, soft drinks containing artificial aromas and flavors, beverages containing fruit juice)
The time required to develop a product – from conception to launch on the market – is steadily shrinking. Since recipes are also becoming ever more complex and a wide range of different types of packaging are now employed, forced stability tests have become absolutely essential, in order to establish a realistic indication of a product’s shelf-life.
Inferences about the shelf-life of a product can only be made if the entire beverage concept is taken into consideration, such as the recipe, filling technology, packaging and distribution.
The most important stress factors in the aging process are heat, light and oxygen.
PET bottles have become a popular form of packaging for non-alcoholic beverages, and their permeability to gas, most especially oxygen, is therefore a critical parameter in the aging process.
The testing process described below operates, of course, on the assumption that the chemical reactions in the aging process are subject to the same mechanisms, whether they occur at temperatures typical for beverage storage or at somewhat elevated temperatures, and that they follow a linear relationship dependent on temperature. The same applies to forced photochemical reactions and to reactions brought about by an increase in the partial pressure of oxygen on the beverage. To verify results from forced testing, they can be compared and correlated to results from real-time tests on the same product.
This method describes the procedure for conducting a stress test for water containing added aroma.
Water with added aroma
The time required to develop a product – from conception to launch on the market – is steadily shrinking. Since recipes are also becoming ever more complex and a wide range of different types of packaging are now employed, forced stability tests have become absolutely essential, in order to establish a realistic indication of a product’s shelf-life.
Inferences about the shelf life of a product can only be made if the entire beverage concept is taken into consideration, such as the recipe, filling technology, packaging and distribution.
The most important stress factors in the aging process are heat, light and oxygen.
PET bottles have become a popular form of packaging for non-alcoholic beverages, and their permeability to gas, most especially oxygen, is therefore a critical parameter in the aging process.
The testing process described below operates, of course, on the assumption that the chemical reactions in the aging process are subject to the same mechanisms, whether they occur at temperatures typical for beverage storage or at somewhat elevated temperatures, and that they follow a linear relationship dependent on temperature. The same applies to forced photochemical reactions and to reactions brought about by an increase in the partial pressure of oxygen on the beverage. To verify results from forced testing, they can be compared and correlated to results from real-time tests on the same product.
This method describes the procedure for conducting a stress test on non-alcoholic beverages.
Non-alcoholic beverages (soft drinks, beverages containing fruit juice)
The time required to develop a product – from conception to launch on the market – is steadily shrinking. Since recipes are also becoming ever more complex and a wide range of different types of packaging are now employed, forced stability tests have become absolutely essential, in order to establish a realistic indication of a product’s shelf-life.
Inferences about the shelf life of a product can only be made if the entire beverage concept is taken into consideration, such as the recipe, filling technology, packaging and distribution.
The most important stress factors in the aging process are heat, light and oxygen.
PET bottles have become a popular form of packaging for non-alcoholic beverages, and their permeability to gas, most especially oxygen, is therefore a critical parameter in the aging process
The testing process described below operates, of course, on the assumption that the chemical reactions in the aging process are subject to the same mechanisms, whether they occur at temperatures typical for beverage storage or at somewhat elevated temperatures, and that they follow a linear relationship dependent on temperature. The same applies to forced photochemical reactions and to reactions brought about by an increase in the partial pressure of oxygen on the beverage. To verify results from forced testing, they can be compared and correlated to results from real-time tests on the same product.