The method is suitable for beer brewed to any original gravity or to any alcohol content.
Volatile compounds in beer are concentrated through distillation and extracted with dichloromethane. The solvent phase is analyzed with a gas chromatograph. The linearity of the detector and the determination of the concentrations of analytes in the sample are achieved by using multiple concentration levels within the relevant range and through evaluation of the relative area under the peaks.
This method describes how to determine the acid consumption or acid capacity of water.
Water intended for use as an ingredient in the production of beer (brewing liquor) or other foods
Determination of the total acidity through titration
This method is used to determine the total titratable acids in beverages and concentrates.
Titratable acidity represents the sum of the free acids present in a beverage, with the exception of the dissolved carbon dioxide (carbonic acid). In fruit juices and the beverages prepared from them, they usually consist of malic acid, citric acid and tartaric acid.
The titration of the degassed beverage sample (freed from carbonic acid) is carried out potentiometrically using 0.25 mol/l sodium hydroxide solution either to a pH of 7.0 calculated as tartaric acid or to a pH of 8.1 calculated as citric acid.
Determination of the steam-volatile acids by means of titration
This method serves as a means for determining the titratable steam-volatile acids in beverages and concentrates
Volatile acids are distilled using steam, and the distillate is analyzed through titration. Sulfurous acid present in the distillate is determined iodometrically and subtracted from the total.
Determination of glucuronolactone by means of ion chromatography and pulsed amperometric detector
This method is suitable for energy drinks and non-alcoholic beverages.
Glucuronolactone is separated by means of a strongly alkaline eluent with an ion exchange column. It is detected and quantified electrochemically using a pulsed amperometric detector (PAD).
Through creating a potential, the ions are oxidized on a gold electrode and induce a measurable charge. To prevent the electrode from being coated over a short time, the potential is then reversed to reduce and release the ions from the electrode.
The method is suitable for the determination of water vapor volatile aroma compounds in beer.
Volatile aroma compounds are driven out of the sample through steam distillation. The ethanolic distillate is saturated with NaCl. Potassium hydrogen sulfite is added to separate carbonyl groups that might interfere with the analysis. The extraction of the aroma compounds is performed by shaking out with dichloromethane and the phases separated by centrifuging.